I dont know why they have to lie about it. At $5/8ft board you’d think I paid for the full 1.5. Edit: I mixed up nominal with actual.

    • Dr. Bob
      link
      fedilink
      English
      52 months ago

      Structural use means load bearing. So no.

      • @[email protected]
        link
        fedilink
        English
        -4
        edit-2
        2 months ago

        Furring strips are used in plenty of places, I provide one example where it is used in most residential homes to support drywall.

        Is it not structural if it’s holding ceiling drywall…? So why are people still bickering that walls aren’t structural when they still hold drywall up…?

        If it’s part of a code wall detail, would that not be structural…?

        What’s with the pedantism over something like this to try and save face over not knowing what a furring strip is?

        • @[email protected]
          link
          fedilink
          English
          82 months ago

          No, that’s is not structural.

          Structural means it’s intended to support and transfer loads in a way that cannot be safely removed.

          Since neither the furring strips or drywall are part of a structural requirement, they are not load bearing.

          • @[email protected]
            link
            fedilink
            English
            -7
            edit-2
            2 months ago

            Drywall is structural, when used on block walls it helps provide lateral support.

            This is why being pedantic usually backfires.

            Drywall is inherently structural.

            Regardless. It’s furring strips, you want to argue furring strips aren’t used in structural applications? They are used in all three applications the person said they haven’t used them in. They also claimed to be a wood wroker elsewhere, so I don’t see how they would use anything structural anyways….

            • @[email protected]
              link
              fedilink
              English
              72 months ago

              This is why being pedantic usually backfires

              No shit. You’re giving us a master class on it right now.

            • @[email protected]
              link
              fedilink
              English
              62 months ago

              Drywall is not structural on block walls. The blocks are structural themselves.

              The drywall may help minimize shifting/settling but the dreary is not a structurally required component of the block wall.

              • @[email protected]
                link
                fedilink
                English
                -8
                edit-2
                2 months ago

                What’s that got to do with furring strips that can be used in structural drywall applications? We are getting too far from the original point.

                You agree drywall is structural and that’s all that matters to this discussion.

                And yes, if the furring strips and drywall are detailed in the plan, they are structural components since it has to be built as designed.

                Just because they can also be used in non-structural uses doesn’t negate their structural use dude.

            • @[email protected]
              link
              fedilink
              English
              12 months ago

              I’m not an architect, but I have stayed at a Holiday Inn.

              The easiest way to think about an element being “structural” or not is is to consider what can happen if you remove that element - will the roof/wall collapse on top of you or not. If the answer is no, the roof/wall will not fall down, it’s not “Structural” or “Load Bearing” If the roof/wall can fall down on if you remove it, it is “structural” or “load bearing”.

              So, using your example, if you were to remove the drywall and furring strips from that cement block wall, will the wall and ceiling be in danger of collapse? If it is, then it was structural. If not, then it wasn’t structural.

              The Architects and Civil Engineers that I have known, do not consider drywall or furring strips to “structural” when designing a building. I’m going with their consensus on this matter.

              • @[email protected]
                link
                fedilink
                English
                -2
                edit-2
                2 months ago

                The Architects and Civil Engineers that I have known, do not consider drywall or furring strips to “structural” when designing a building. I’m going with their consensus on this matter.

                Jesus Christ, just because it can be used in non-structural application does not mean it can’t be used structurally else where. It’s also hilarious that you think we are ever going to think this has come up in a conversation before lmfao. You clearly are already taking out of your ass, but I’ll bite since the idiocy people are coming up with is entertaining as hell….

                Furring strips and drywall are both used in structural applications since they are both structural components.

                If a ceiling is strapped with them to provide lateral support and the ceiling is also cladded with drywall for additional lateral support. Congrats, both just got used in a load bearing application… I’m sorry apparently the architects and engineers you use haven’t come across this very common application?

                You clearly have no clue on the matter lmfao.

        • Dr. Bob
          link
          fedilink
          English
          12 months ago

          Furring strips and drywall don’t count as load bearing. Structural means that it carries the weight of the overlying structure. Basically if the building falls down if that element is missing, it’s structural. So staircases for instance are almost never structural. Many interior walls are not load bearing so they can get knocked down without consequence. You can also split a room by building a wall that won’t be load bearing.

          • @[email protected]
            link
            fedilink
            English
            -22 months ago

            Furring strips and drywall don’t count as load bearing.

            Except for the thousands of use cases where they are used for lateral bracing to support the structure….

            Like in shear walls… strapped drywall ceilings… load bearing walls….

            Yes they can be used non-structurally, I’ve never claimed otherwise, yet you are ignoring the fact that they can, and are used in load bearing structural applications……

    • @[email protected]
      link
      fedilink
      English
      -2
      edit-2
      2 months ago

      That was one example, you can also strap roofs to install sheet metal cladding. Is that not structural? Strap a ceiling? There’s a ceiling use for you.

      I figured if I gave you a real world example you could do a little research of your own. Even googling 2x2 will get you a big box store furring strip page. You should know what furring strips are if you are in the industry.

      • @[email protected]
        link
        fedilink
        English
        22 months ago

        No, that’s not structural since the furring strips are not integral to load bearing capacity of the structure.

        In your sheet metal example, they are only there for visual reasons - to help keep the roof flat. The roof can be put down without the furring strips. It might bend, but it still function as a roof.

        • @[email protected]
          link
          fedilink
          English
          -3
          edit-2
          2 months ago

          The roof can be put down without the furring strips. It might bend, but it still function as a roof.

          What…? Roof trusses go parallel with the length of the cladding panel, you require furring strips on the perpendicular to install them. Just like in a wall with the studs vertical, you need horizontal furring to install them.

          These required larger furring strips due to truss spacing.

          Furring strips are not visual lmfao. They are structural components in a lot of assemblies. Without knowing the assembly you can’t say if they are or aren’t structural, that’s the entire point I’ve been trying to make here. You aren’t the quickest one are you? I’ve pointed this out multiple times. There are thousands of use cases where furring strips are structural. To say they aren’t structural is fucking asinine lmfao.

          • @[email protected]
            link
            fedilink
            English
            32 months ago

            Those aren’t furring strips in that photo. That’s dimensional lumber. In this case, those spans are large enough that they require the strength of actual lumber.

            • @[email protected]
              link
              fedilink
              English
              -52 months ago

              Those aren’t furring strips in that photo. That’s dimensional lumber. In this case, those spans are large enough that they require the strength of actual lumber.

              Yes I literally just explained that in detail in the comment you responded to……

              • @[email protected]
                link
                fedilink
                English
                12 months ago

                Can I just ask for clarification?

                You: here is furring strips being used as support, with a screenshot

                Other Poster: the things you are referring to as furring strips, are actually not furring strips

                You: Thats what I said in the first post!

                Aren’t you agreeing here that you are mistaken on what a furring strip is?

                • @[email protected]
                  link
                  fedilink
                  English
                  -2
                  edit-2
                  2 months ago

                  If the trusses were closer together you would use the 2x2 furring strips since it could support the weight. Since it can’t support the weight you need to use 2x4s so the picture isn’t showing 2x2 furring strips but if you aren’t a fucking moron you would realize that’s where they are used.

                  Buddy got caught saying something structural isn’t, so now they’re throwing shit at the wall to save face. And unfortunately down in this part of the thread is all the the fucking morons.

                  People in the industry would know what I was talking about, clearly it’s a bunch of people who aren’t since I apparently need to explain it in this section like people are 6 years old.

                  2x2 furring strips are fucking structural and are used in thousands of uses where they are structural. Yet this moron is claiming they aren’t lmfao. You guys are fucking idiots lmfao.

                  • @[email protected]
                    link
                    fedilink
                    English
                    1
                    edit-2
                    2 months ago

                    I dont really have a leg in this race, it does seem like throughout this thread you do showcase a lot of working knowledge.

                    Gotta say its confusing figuring out what the actual issue here is in coming to an understanding.