75 degrees = 68 degrees. No wonder I couldn’t get things to adhere well sometimes.

As a side note, the temp varies wildly along the plate base. An enclosure would definitely help here.

Has anyone else tested the actual temps versus the set/displayed temps and noticed a difference?

  • @eggspresso
    link
    English
    3311 months ago

    Keep in mind IR thermometers are sensitive to the reflectivity/emissivity of the materials they are used on, and the shiny PEI surface can be a bit tricky. Try measuring the temperature of a mirror that your warmed up with your hand and you’ll see a similar problem.

    If you want to test more accurately, put some matte tape on the bed and then measure the temperature then.

    That said there is also a chance for the heat bed to be a bit lower than target temperature, since the temperature control and feedback occurs at the bottom of the bed where the thermistor is, not at the top, and is separated by a layer of magnetic adhesive and coated metal.

    • @[email protected]
      link
      fedilink
      English
      511 months ago

      Agree. Thing that matters is consistency of measurement, but thermistors tend to not drift very much. One thing for op to keep in mind is that thermistors tend to be mounted to the bottom of the bed and there will be some temperature difference between the bottom on the top - especially if the printer hasn’t had the opportunity to soak. The other thing to keep in mind is how the terminator is attached to the bed. On my i3 it was just a piece of kapton tape, which meant there was often an air gap between the thermistor and the bed. I’m sure this resulted in quite a bit of weirdness.

    • FuglyDuck
      link
      fedilink
      English
      311 months ago

      If you want to test more accurately, put some matte tape on the bed and then measure the temperature then.

      hehe. I use dots left over from my first-layer test prints. or other 1-2 layer height plastics. it can be anything that’s thin, and not shiny.

    • ROLLER
      link
      fedilink
      111 months ago

      @eggspresso most infrared (IR) thermometers have a way to adjust the emissivity. Emissivity is basically how well the object gives off IR. As you suggested black electrical insulating tape is good. If it it thin tape then put two layers down. The emissivity of this is 95% which can be input into the thermometer.