    I’ve alwaus been fascinated how Limeys are so adamant about how American 110v homes are inferior, but they all have an insane fear of electricity.

    • Rustmilian@lemmy.world
      link
      fedilink
      English
      arrow-up
      5
      arrow-down
      1
      ·
      edit-2
      9 months ago

      240V 60Hz is actually the US standard, the actual output from the outlets however is different and depends on what device it’s intended for. High volt outlets for high volt devices use NEMA 6-15P & 6-50P connections.

        • Rustmilian@lemmy.world
          link
          fedilink
          English
          arrow-up
          4
          arrow-down
          3
          ·
          edit-2
          9 months ago

          Electric Range Outlets

          220V

          Like I already said, US households are wired to the 240V 60Hz standard, it just depends on what device the outlet is intended for. The outlet can be anywhere from 110V for low volt appliances using NEMA 1-15P & 5-15R all the way up to 240V for high volt appliances using NEMA 6-15P & 6-50P.

          Wikipedia

          Today, virtually all American homes and businesses have access to 120 and 240 V at 60 Hz. Both voltages are available on the three wires (two “hot” legs of opposite phase and one “neutral” leg).

          can’t go wrong with these bad boys.

          • HandMadeArtisanRobot@lemmy.world
            link
            fedilink
            English
            arrow-up
            3
            ·
            edit-2
            9 months ago

            Yes, I know that many US homes have 220V outlets for electric ranges or water heaters but most outlets are not and the ones that are are not typically accessible for general use. It’s silly to say “240V 60Hz is actually the US standard” in this context since most US residents aren’t going to have one accessible as a special outlet just for a kettle. Or if they do, they better tell their guests before they accidentally plug in a blender.

            Edit: As an aside, I used to work at a restaurant that had a 240V outlet accessible for a commercial belt-driven toaster. One day I decided it was too slow and plugged in a regular slot toaster when nobody was looking. Oh man, It glowed scary bright! I only felt comfortable using for a few seconds at a time, but it handled English muffins like a champ.

            • Rustmilian@lemmy.world
              link
              fedilink
              English
              arrow-up
              1
              ·
              edit-2
              9 months ago

              I have one I can easily access right behind my stovetop & dryer. Even if I didn’t, you literally can’t go wrong with these bad boys. It’s not like it’s a special connection, it’s literally just the usual 3 prong. If you know about it in the first place, it’s not hard to access. It’s not like the stove is bolted into the fuckin wall in 99% of US houses.

                • Rustmilian@lemmy.world
                  link
                  fedilink
                  English
                  arrow-up
                  1
                  ·
                  edit-2
                  9 months ago

                  You likely DO have at least one, they’re just installed per-code. If you have a house that’s not had it’s electric updated for over 100 years, then maybe not, but damn if that’s the case your shits probably gonna burn soon.
                  Maybe check the outlet behind your dryer. Usually they’re either behind the stove, the dryer, or one in the basement for the boiler, possibly one for one of those big ass AC units if you have those.

            • nBodyProblem@lemmy.world
              link
              fedilink
              arrow-up
              1
              ·
              9 months ago

              From a utility side perspective it’s true to say 240v is the standard we just wire our outlets to use one of the two hot wires instead of both of them.