I have a back bedroom with sealed windows, and it gets dry sometimes. It’s for a person with horrible allergies. This room is so clean you could eat off the floor so to speak. I run a humidifier set to 60% with distilled water for the person in there. When I checked on it last night to see if it needed to be filled, the humidity had gone up to 82%. This was because a ceiling fan had been left on and the sensor in the humidifier wasn’t getting correct data from the moving air (I think). My hallway smoke / Co2 detector went off as soon as I opened the bedroom door. It would not clear until I pointed a hair dryer at it, then it shut the hell up.

TLDR: My smoke detector doesn’t like humidity all of a sudden?? and went off and would not clear. It has been more humid than that in the entire house without humidifiers running, and I have the same detectors in other locations with no issues.

  • spittingimage@lemmy.world
    link
    fedilink
    arrow-up
    24
    ·
    1 year ago

    I’ve had a smoke detector that would routinely trigger when the clothes dryer was operating. I think they detect steam as well as smoke.

      • JackFrostNCola@lemmy.world
        link
        fedilink
        English
        arrow-up
        20
        ·
        1 year ago

        Certain types of smoke detectors dont detect ‘smoke’ or ‘steam’ exactly, but they monitor a small section of air in the unit and if there is enough particulate matter in the air the sensor is triggered and it goes off.
        Because of this they are sensitive to aresols too, such as spray on deoderant.

        • skulblaka@kbin.social
          link
          fedilink
          arrow-up
          8
          ·
          1 year ago

          This is almost certainly the correct answer. If it’s a photoelectric-type detector it’ll be set off by any interruption of the beam. This can be smoke, steam/vapor, dust, etc.

          You can replace them with ionization type smoke alarms (or “dual type” alarms) and this will make it less sensitive to non-smoke interference.

    • Ilovethebomb@lemmy.ml
      link
      fedilink
      arrow-up
      7
      ·
      1 year ago

      I work with fire alarm systems, as others have said, smoke, steam, dust, and even insects inside the detection chamber will trigger a photoelectric smoke det.

  • Drusas@kbin.social
    link
    fedilink
    arrow-up
    26
    arrow-down
    3
    ·
    1 year ago

    So it’s the smoke detector, not the CO detector? These are separate devices. A smoke detector will typically be on the ceiling and a CO detector will typically be close to the floor.

    I’ve had smoke detectors which are set off by steam, such as from a hot shower. You can replace it with a style of detector which operates differently, not using photoelectricity to be triggered. Keeping batteries fresh is also supposed to help, but I don’t know if it really does.

    That said, you may want an alarm for humidity because 82% is quite high and may cause damage to the home.

  • fiat_lux@kbin.social
    link
    fedilink
    arrow-up
    21
    ·
    edit-2
    1 year ago

    Smoke detectors frequently work by having a teensy little radioactive emitter and a teensy radioactivity detector somewhere close to it. It works a bit like a laser trap in a video game or movie, if you break the laser-beam by walking through it, it triggers the alarm because the detector can no longer see the beam.

    But it doesn’t have to be smoke. Water particles will do it, dust can do it, especially when there’s construction work going on putting the dust in the air… it doesn’t matter. It just needs to be enough to break the connection between emitter and detector.

    Wet steam and the vapor from humidifiers is pretty effective at triggering it because the droplets are bigger than regular humidity.

  • krayj
    link
    fedilink
    English
    arrow-up
    7
    ·
    edit-2
    1 year ago

    I assume you mean “CO” detector. CO2 is Carbon Dioxide and I don’t think you went out and purchased and installed a detector for that.

    High humidity levels can absolutely cause a false alarm on a CO detector. Example: https://safeinhomeair.com/carbon-monoxide-humidity/

    I’ll also point out that not all CO detectors are created equal. There was a lot of news about this earlier this year where a number of CO detectors sold on Amazon simply did not work, or did not meet published safety and detection standards. Here’s an example of some of the serious warnings that were published: https://www.cpsc.gov/Newsroom/News-Releases/2023/CPSC-Warns-Consumers-to-Immediately-Stop-Using-GLBSUNION-and-CUZMAK-Digital-Display-Carbon-Monoxide-Detectors-Due-to-Failure-to-Alert-Consumers-to-Deadly-Carbon-Monoxide-Sold-on-Amazon-com#:~:text=The CO detectors were sold,on www.SaferProducts.gov . Following that announcement, there were several other brands and models that were flagged as being non-compliant. If you haven’t done so already, find your make/model and verify that it’s not one of the sub-standard units that were pawned on Amazon for years.

    CO detectors also need to be replaced (they don’t last forever). Most use chemistry to detect CO levels, and that chemistry begins degrading as soon as the unit is built. Some last just a couple years, some are designed to last up to 10 years, but the point is - they all go bad eventually. How old is your detector?

    Smoke detectors can also be fooled by high moisture.

    I usually don’t buy smoke/CO combo units (I prefer separate detectors for each thing), but I do have a combo unit in a hallway in my upstairs - and it’s got a great feature where it announces by voice what is triggering the alarm (“smoke” or “carbon monoxide”). Does yours do that or does it just sound the same alarm regardless of what was detected?

  • all-knight-party@kbin.run
    link
    fedilink
    arrow-up
    3
    arrow-down
    1
    ·
    1 year ago

    I’m far from an expert on humidity or electronics, but if there was any condensation it’s possible a circuit got bridged inside the alarm and triggered it.

  • Anamnesis@lemmy.world
    link
    fedilink
    arrow-up
    2
    ·
    1 year ago

    This sounds wild but you don’t live near Seattle, do you? We just had a minor earthquake and the next morning all my smoke detectors went hog wild. Apparently that can happen?