An electrician ‘fixed’ an issue by making this hole in a basement cinder block wall.

… how do I put that box back in or fix the wall or something?

Inside the box are two capped (hot) wires.

The pipe seems to be copper. Doesn’t bend or anything. It can’t (at least easily) be pushed back in.

I had wanted to use cement paste… but like what do I do about the box? I guess I could paste everything except the metal pipe but geez: then i still have this sketchy box hanging out.

Images: https://imgur.io/a/yBh2QBD (posted from mobile and don’t think the images went through)

Any ideas?

  • @[email protected]
    link
    fedilink
    English
    277 months ago

    Tell him to come back and finish the job, because that is shit, and you’re paying him to do the whole job, not half-ass it.

    • @csm10495OP
      link
      English
      27 months ago

      Funny enough he claimed this was the job and the only way to fully fix it would be to replace the whole wire pipe and break a line up the wall and fix it… and charge at least a thousand bucks more for the pleasure.

      Ridiculous.

      • @[email protected]
        link
        fedilink
        47 months ago

        Nope. He could have just properly installed the box flush in that wall using plaster of paris or something. He was just to lazy.

  • @[email protected]
    link
    fedilink
    4
    edit-2
    7 months ago

    You probably want to slip some conduit around the wire to protect it from the mortar, patch the hole, then use a surface mount box screwed to the wall with the wire fed in the back.

    • @csm10495OP
      link
      English
      1
      edit-2
      7 months ago

      The wire is inside a copper pipe. The line going to the box is a copper pipe with 2 wires in it. (I think its already protected.)

      • @[email protected]
        link
        fedilink
        27 months ago

        If that’s the case, I’d probaby try to cut the copper pipe back, install a 90 degree fitting and do the rest of what I suggested.

  • @[email protected]
    link
    fedilink
    English
    27 months ago

    Any chance of disconnecting the wire and pulling it out of the conduit? Then you could cut the conduit off inside the wall with a reciprocating saw or better, an oscillating tool, abandoning it.

    • @[email protected]
      link
      fedilink
      27 months ago

      Electrically speaking it is in the proper housing, but the box is not secured, so I would ding it for that at the very least. I agree about cutting the conduit back and putting in a proper secure box and then cementing around the box. You could also use a surface mount box. In that case you would cut the existing conduit back, put a 90 degree elbow with a enough conduit to extend past the wall edge. Patch the wall and then install a surface mount box where the wires are connected in.

    • @csm10495OP
      link
      English
      2
      edit-2
      7 months ago

      The wire to the box is inside a copper pipe. Its wall -> copper pipe -> electrical box.

      The wires are in the copper pipe.

      • [email protected]A
        link
        17 months ago

        Right then that’s a conduit and you can probably bend it back.

        • @csm10495OP
          link
          English
          17 months ago

          It didn’t want to bend. I wound up hitting it many times with a hammer to bend it inward… not fun but hey it may work out.

          • [email protected]A
            link
            27 months ago

            Then I’m confused about how this looked before, was the conduit always sticking out?

            • @csm10495OP
              link
              English
              17 months ago

              Nope. There was an access box flush in the wall. He broke the wall, pulled it out and here we are.

              • @[email protected]
                link
                fedilink
                17 months ago

                Wow, what did he “fix” then? He did a terrible job. I understand an electrician not fixing the cement block, but they should have properly installed and secured the box flush with the concrete.