Hi, I have built a microvawe transformer spotwelder, I have put a single turn of welder wire for in the secondary and I’m timing it with arduino. Worth mentioning it was/is a 230V transformer. Electrodes are sharpened copper rods. I believe the voltage is still high. The spotwelds it produces are slightly discolored and not as strong as you would expect. Is this design fundamentally borked? Is there anything else I can make to make it better? Photo from test stage before it was built into a project box, it is less “shocking” now.

  • @[email protected]OP
    link
    fedilink
    English
    19 months ago

    I have 230V or 400V three phase. I live in the EU. So this cannot be solved without replacing the winding on the transformer I guess.

    • @[email protected]
      link
      fedilink
      English
      18 months ago

      If you have a 230V supply and a 230V transformer, you are fine. I believe they thought you were using a 120V supply on a 230V transformer.

      Raising the input voltage will probably not get you what you want.

    • @BigDanishGuy
      cake
      link
      English
      19 months ago

      If it’s just a matter of getting a larger voltage, then you already got 400V. No need for new windings, unless the insulation on the primary can’t handle 400V.