• Buddahriffic@lemmy.world
    link
    fedilink
    arrow-up
    13
    ·
    edit-2
    4 months ago

    There is a wooosh here, though I’m not sure it’s on you or me.

    In case it’s you, it is just a bong and doesn’t go anywhere. That bit on the bottom is just the stand and the pipe doesn’t connect to anything below the floor, it’s just sitting in the cupboard.

    If you already knew this, then the wooosh is on me lol.

    It’s an effective way to hide a bong in plain sight because it looks like it’s a vent pipe. But I do agree with those saying don’t smoke something with a PVC-based pipe (though I’d extend that to say your smoking utensil shouldn’t involve any plastic whatsoever other than maybe o-rings, but my glass-only rig is able to seal well without them).

    Edit: a word

    • lloydxmas@lemmy.world
      link
      fedilink
      arrow-up
      13
      ·
      edit-2
      4 months ago

      It’s on you. They’re talking about the 90 degree elbow behind the bong that heads upwards. It’s piped like it’s to a vent, but the location relative to the cabinet opening means the vent for the sink is… between you and the sink

      [edit] so their comment is saying “yea I see the bong, but that plumbing work is shit and I can’t get past it”

      • Buddahriffic@lemmy.world
        link
        fedilink
        arrow-up
        3
        ·
        edit-2
        4 months ago

        Ah, yeah, I see that now, rereading what they originally said.

        Out of curiosity, what is the issue with using a vent 90 degree elbow vs whatever should be used there instead?

        Btw, I’m assuming that’s the drain pipe coming from the sink above rather than a vent, especially since it looks like the dishwasher drain is attached to the horizontal part… Wait, is it attached to the bottom of the horizontal section??

        Edit: looks like it’s sloping downwards the wrong way, too, if it is a drain pipe.

        • jubilationtcornpone
          link
          fedilink
          English
          arrow-up
          5
          ·
          4 months ago

          Drains should always have a P-trap within so many inches of the drain opening. That prevents sewer gas from escaping from the drain. This is what should be there if it’s a sink drain.

          The issue with a vent 90/elbow in a sewer line is that they slow the water flow and can easily become obstructed. Normal elbows are curved to help prevent the water flow from slowing down.

          • Buddahriffic@lemmy.world
            link
            fedilink
            arrow-up
            1
            ·
            4 months ago

            Thanks for the info!

            Why does the p-trap need to be so close to the opening? As long as it’s somewhere along the line, shouldn’t it prevent gases from flowing? My own kitchen sink doesn’t have a p-trap in the cupboard below but I assume there’s one downstream because I’ve never noticed sewer smells in the kitchen. I figured it was the developers being cheap as soon as I noticed it, but they seem to at least have prevented the issue another way, so it’s hard to say if they were cheap or just efficient (or maybe neither if it’s just a p-trap in a different location).

            My bathroom sink does have a p-trap under the sink though, so I’m still confused as to why it’s done one way in one spot and another in the other.

            Only other guess I have at this point is it was done that way to simplify fitting the drain pipes under the sink because the hole for the pipe is directly underneath the one sink drain and it just feeds directly down via a vertical pipe, with the other sink’s drain feeding into that via a y-connection.

            • jubilationtcornpone
              link
              fedilink
              English
              arrow-up
              3
              ·
              edit-2
              4 months ago

              One problem with a “central” P-trap is that if it were done that way, you’re going to get nasty smells somewhere. Sewage frequently doesn’t make it out of your house as fast as you think it will and running water down the drain changes the air pressure in the drain line to varying degrees.

              The main reason it’s positioned so close to the drain opening is to accommodate venting. Every drain opening has to be vented, typically with a pipe going through the wall to a vent stack in the attic, to prevent the P-trap from being sucked dry when you do something like flush the toilet or run the clothes washer.

              Ever run the washing machine and hear a sink on the other side of the house gurgling during the drain cycle? That’s because the washer draining changes the air pressure in the sewer line and the sink isn’t properly vented causing air to bubble through the the P-trap.

              • Buddahriffic@lemmy.world
                link
                fedilink
                arrow-up
                1
                ·
                4 months ago

                Ok, I don’t ever hear gurgling from other drains, so whatever they did end up doing must be set up properly. There is what looks like a capped vent that ends just a bit above the cupboard floor, guessing it acts as a buffer for air pressure to allow it to fluctuate without venting the gases into my living space.

                • jubilationtcornpone
                  link
                  fedilink
                  English
                  arrow-up
                  3
                  ·
                  4 months ago

                  Might be an air admittance valve. Those are usually used when venting to the roof isn’t possible or practical.

                  Plumbing is one of those things that’s sort of an art. You can do a whole bunch of shit wrong and have it still technically function properly. Nobody will know except you and the next person who actually knows what they’re looking at.

                  • Buddahriffic@lemmy.world
                    link
                    fedilink
                    arrow-up
                    1
                    ·
                    4 months ago

                    It’s surprising how much depth there is to plumbing. And alarming how easy it is to become overconfident that one has it mostly figured out.