Hey folks,

I’m not sure what I’m doing wrong. I’m printing PETG (https://kingroon.com/collections/petg-filament?) on my Neptune 3 Plus. It’s sort of like it starts (almost) ok, sticks to the plate just fine, then a few layers up it seems to almost have inconsistent extrusion (or maybe even trouble pulling the filament?) leading to holes, etc. till the model just falls apart. See linked photos for about where I give up each time.

I’m printing with Cura and 240C printing, 90C on the build plate. 45mm/s (I’ve gone down from 60mm/s). Retraction on, no z-hop. 60% fan, though I’ve tried it with 20% and 100% fan as well.

The filament is in a dryer at 55C. Funny enough I printed basically perfectly (without drying, straight out of the bag) with default settings the first time I printed. The second time and on, have had this problem… and have had it in the dryer.

Any ideas would be much appreciated. Thanks!

Edit: In case its useful, I’m printing this piece: https://file.io/D9jxYq4KOrL7 which is a small remix of a piece from https://www.printables.com/model/130507-bolt-action-pen-for-pilot-g2-cartridges

  • csm10495OP
    link
    fedilink
    English
    arrow-up
    1
    ·
    3 hours ago

    Honestly not very different timing: maybe 25 minutes instead of 20 to be failing.

    Trying more than 1 is an interesting idea. Too bad I don’t need more than 1 lol. Maybe I’ll print a benchy elsewhere on the plate. Though why wouldn’t more cooling help offset similarly?

    • teotwaki@lemmy.world
      link
      fedilink
      English
      arrow-up
      3
      ·
      3 hours ago

      It could be a case of too much cooling, while simultaneously being too much heat.

      If you’re blowing so much air that the filament instantly solidifies when it leaves the nozzle, it’s not going to bond with anything else. It’s also interesting that the first layers are fine (when the part cooling fan is typically not running), but problems start when the part cooling fan turns on.

      Have you tried without part cooling at all? Another thing is that your part cooling might be cooling down the tip of the nozzle, causing tiny partial clogs, which are cleared every so often by friction.