• Badabinski@kbin.earth
    link
    fedilink
    arrow-up
    7
    ·
    1 month ago

    I dunno if you would want to run raidz2 with disks this large. The resilver times would be absolutely bazonkers, I think. I have 24 TB drives in my server and run mirrored vdevs because the chances of one of those drives failing during a raidz2 resilver is just too high. I can’t imagine what it’d be like with 30 TB disks.

    • taladar
      link
      fedilink
      English
      arrow-up
      4
      ·
      1 month ago

      A few years ago I had a 12 disk RAID6 array and the power distributor (the bit between the redundant PSUs and the rest of the system) went and took 5 drives with them, lost everything on there. Backup is absolutely essential but if you can’t do that for some reason at least use RAID1 where you only lose part of your data if you lose more than 2 drives.

    • killabeezio@lemm.ee
      link
      fedilink
      English
      arrow-up
      2
      ·
      1 month ago

      Yeah I agree. I just got 20tb in mine. Decided to just z2, which in my case should be fine. But was contemplating the same thing. Going to have to start doing z2 with 3 drives in each vdev lol.

    • sugar_in_your_tea
      link
      fedilink
      English
      arrow-up
      1
      ·
      edit-2
      1 month ago

      Is RAID2 ever the right choice? Honestly, I don’t touch anything outside of 0, 1, 5, 6, and 10.

      Edit: missed the z, my bad. I don’t use ZFS and just skipped over it.

        • sugar_in_your_tea
          link
          fedilink
          English
          arrow-up
          1
          ·
          1 month ago

          Yeah, I noticed the “z” in there shortly after posting. I don’t use ZFS much, so I kinda skimmed over it.