• carbon on contacts due to arc burn can also act as a resistance and create fire
  • burned wires must be also snipped or much better, replaced to avoid electric fire.
  • TWeaK@lemm.ee
    link
    fedilink
    English
    arrow-up
    2
    ·
    14 hours ago

    Back in the day your monitor(s) would have been drawing a lot more power (I’m talking way back with CRT monitors). Also, your PC doesn’t draw 750 watts all the time if at all - 750W is the max rating for the power supply. Even if you did have a very power hungry system (read: GPU) it would only draw that while running full whack, most of the time the PC will idle at lower clock speeds and lower power.

    Your soldering irons are probably only 25W, certainly less than 100W (unless you’re showing off). The big things are generally anything involving heating, but many of the things at your desk probably don’t use that much. After heating it’s motors. And, again, these things are generally not all on at the same time.

    Suffice it to say, there isn’t really any higher risk to the volume and type of load we have today than back when electricity was first installed in houses. It certainly should be said that the installations are much safer now than they used to be, where even a faulty install like this shouldn’t lead to a fire - if your cable is installed in ducting or kopex then even if a faulty termination heats the cable up there won’t be anything in contact with it to start a fire.

    But you should still get check these things checked out. The layers of redundancy by design are great, but you don’t want holes in the Swiss cheese to line up - that’s when bad things happen.